| /* SPDX-License-Identifier: GPL-2.0-only */ | |
| /* | |
| * Universal power supply monitor class | |
| * | |
| * Copyright © 2007 Anton Vorontsov <cbou@mail.ru> | |
| * Copyright © 2004 Szabolcs Gyurko | |
| * Copyright © 2003 Ian Molton <spyro@f2s.com> | |
| * | |
| * Modified: 2004, Oct Szabolcs Gyurko | |
| */ | |
| #ifndef __LINUX_POWER_SUPPLY_H__ | |
| #define __LINUX_POWER_SUPPLY_H__ | |
| #include <linux/device.h> | |
| #include <linux/workqueue.h> | |
| #include <linux/leds.h> | |
| #include <linux/rwsem.h> | |
| #include <linux/list.h> | |
| #include <linux/spinlock.h> | |
| #include <linux/notifier.h> | |
| /* | |
| * All voltages, currents, charges, energies, time and temperatures in uV, | |
| * µA, µAh, µWh, seconds and tenths of degree Celsius unless otherwise | |
| * stated. It's driver's job to convert its raw values to units in which | |
| * this class operates. | |
| */ | |
| /* | |
| * For systems where the charger determines the maximum battery capacity | |
| * the min and max fields should be used to present these values to user | |
| * space. Unused/unknown fields will not appear in sysfs. | |
| */ | |
| enum { | |
| POWER_SUPPLY_STATUS_UNKNOWN = 0, | |
| POWER_SUPPLY_STATUS_CHARGING, | |
| POWER_SUPPLY_STATUS_DISCHARGING, | |
| POWER_SUPPLY_STATUS_NOT_CHARGING, | |
| POWER_SUPPLY_STATUS_FULL, | |
| }; | |
| /* What algorithm is the charger using? */ | |
| enum power_supply_charge_type { | |
| POWER_SUPPLY_CHARGE_TYPE_UNKNOWN = 0, | |
| POWER_SUPPLY_CHARGE_TYPE_NONE, | |
| POWER_SUPPLY_CHARGE_TYPE_TRICKLE, /* slow speed */ | |
| POWER_SUPPLY_CHARGE_TYPE_FAST, /* fast speed */ | |
| POWER_SUPPLY_CHARGE_TYPE_STANDARD, /* normal speed */ | |
| POWER_SUPPLY_CHARGE_TYPE_ADAPTIVE, /* dynamically adjusted speed */ | |
| POWER_SUPPLY_CHARGE_TYPE_CUSTOM, /* use CHARGE_CONTROL_* props */ | |
| POWER_SUPPLY_CHARGE_TYPE_LONGLIFE, /* slow speed, longer life */ | |
| POWER_SUPPLY_CHARGE_TYPE_BYPASS, /* bypassing the charger */ | |
| }; | |
| enum { | |
| POWER_SUPPLY_HEALTH_UNKNOWN = 0, | |
| POWER_SUPPLY_HEALTH_GOOD, | |
| POWER_SUPPLY_HEALTH_OVERHEAT, | |
| POWER_SUPPLY_HEALTH_DEAD, | |
| POWER_SUPPLY_HEALTH_OVERVOLTAGE, | |
| POWER_SUPPLY_HEALTH_UNDERVOLTAGE, | |
| POWER_SUPPLY_HEALTH_UNSPEC_FAILURE, | |
| POWER_SUPPLY_HEALTH_COLD, | |
| POWER_SUPPLY_HEALTH_WATCHDOG_TIMER_EXPIRE, | |
| POWER_SUPPLY_HEALTH_SAFETY_TIMER_EXPIRE, | |
| POWER_SUPPLY_HEALTH_OVERCURRENT, | |
| POWER_SUPPLY_HEALTH_CALIBRATION_REQUIRED, | |
| POWER_SUPPLY_HEALTH_WARM, | |
| POWER_SUPPLY_HEALTH_COOL, | |
| POWER_SUPPLY_HEALTH_HOT, | |
| POWER_SUPPLY_HEALTH_NO_BATTERY, | |
| POWER_SUPPLY_HEALTH_BLOWN_FUSE, | |
| POWER_SUPPLY_HEALTH_CELL_IMBALANCE, | |
| }; | |
| enum { | |
| POWER_SUPPLY_TECHNOLOGY_UNKNOWN = 0, | |
| POWER_SUPPLY_TECHNOLOGY_NiMH, | |
| POWER_SUPPLY_TECHNOLOGY_LION, | |
| POWER_SUPPLY_TECHNOLOGY_LIPO, | |
| POWER_SUPPLY_TECHNOLOGY_LiFe, | |
| POWER_SUPPLY_TECHNOLOGY_NiCd, | |
| POWER_SUPPLY_TECHNOLOGY_LiMn, | |
| }; | |
| enum { | |
| POWER_SUPPLY_CAPACITY_LEVEL_UNKNOWN = 0, | |
| POWER_SUPPLY_CAPACITY_LEVEL_CRITICAL, | |
| POWER_SUPPLY_CAPACITY_LEVEL_LOW, | |
| POWER_SUPPLY_CAPACITY_LEVEL_NORMAL, | |
| POWER_SUPPLY_CAPACITY_LEVEL_HIGH, | |
| POWER_SUPPLY_CAPACITY_LEVEL_FULL, | |
| }; | |
| enum { | |
| POWER_SUPPLY_SCOPE_UNKNOWN = 0, | |
| POWER_SUPPLY_SCOPE_SYSTEM, | |
| POWER_SUPPLY_SCOPE_DEVICE, | |
| }; | |
| enum power_supply_property { | |
| /* Properties of type `int' */ | |
| POWER_SUPPLY_PROP_STATUS = 0, | |
| POWER_SUPPLY_PROP_CHARGE_TYPE, | |
| POWER_SUPPLY_PROP_CHARGE_TYPES, | |
| POWER_SUPPLY_PROP_HEALTH, | |
| POWER_SUPPLY_PROP_PRESENT, | |
| POWER_SUPPLY_PROP_ONLINE, | |
| POWER_SUPPLY_PROP_AUTHENTIC, | |
| POWER_SUPPLY_PROP_TECHNOLOGY, | |
| POWER_SUPPLY_PROP_CYCLE_COUNT, | |
| POWER_SUPPLY_PROP_VOLTAGE_MAX, | |
| POWER_SUPPLY_PROP_VOLTAGE_MIN, | |
| POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN, | |
| POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN, | |
| POWER_SUPPLY_PROP_VOLTAGE_NOW, | |
| POWER_SUPPLY_PROP_VOLTAGE_AVG, | |
| POWER_SUPPLY_PROP_VOLTAGE_OCV, | |
| POWER_SUPPLY_PROP_VOLTAGE_BOOT, | |
| POWER_SUPPLY_PROP_CURRENT_MAX, | |
| POWER_SUPPLY_PROP_CURRENT_NOW, | |
| POWER_SUPPLY_PROP_CURRENT_AVG, | |
| POWER_SUPPLY_PROP_CURRENT_BOOT, | |
| POWER_SUPPLY_PROP_POWER_NOW, | |
| POWER_SUPPLY_PROP_POWER_AVG, | |
| POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN, | |
| POWER_SUPPLY_PROP_CHARGE_EMPTY_DESIGN, | |
| POWER_SUPPLY_PROP_CHARGE_FULL, | |
| POWER_SUPPLY_PROP_CHARGE_EMPTY, | |
| POWER_SUPPLY_PROP_CHARGE_NOW, | |
| POWER_SUPPLY_PROP_CHARGE_AVG, | |
| POWER_SUPPLY_PROP_CHARGE_COUNTER, | |
| POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT, | |
| POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX, | |
| POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE, | |
| POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX, | |
| POWER_SUPPLY_PROP_CHARGE_CONTROL_LIMIT, | |
| POWER_SUPPLY_PROP_CHARGE_CONTROL_LIMIT_MAX, | |
| POWER_SUPPLY_PROP_CHARGE_CONTROL_START_THRESHOLD, /* in percents! */ | |
| POWER_SUPPLY_PROP_CHARGE_CONTROL_END_THRESHOLD, /* in percents! */ | |
| POWER_SUPPLY_PROP_CHARGE_BEHAVIOUR, | |
| POWER_SUPPLY_PROP_INPUT_CURRENT_LIMIT, | |
| POWER_SUPPLY_PROP_INPUT_VOLTAGE_LIMIT, | |
| POWER_SUPPLY_PROP_INPUT_POWER_LIMIT, | |
| POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN, | |
| POWER_SUPPLY_PROP_ENERGY_EMPTY_DESIGN, | |
| POWER_SUPPLY_PROP_ENERGY_FULL, | |
| POWER_SUPPLY_PROP_ENERGY_EMPTY, | |
| POWER_SUPPLY_PROP_ENERGY_NOW, | |
| POWER_SUPPLY_PROP_ENERGY_AVG, | |
| POWER_SUPPLY_PROP_CAPACITY, /* in percents! */ | |
| POWER_SUPPLY_PROP_CAPACITY_ALERT_MIN, /* in percents! */ | |
| POWER_SUPPLY_PROP_CAPACITY_ALERT_MAX, /* in percents! */ | |
| POWER_SUPPLY_PROP_CAPACITY_ERROR_MARGIN, /* in percents! */ | |
| POWER_SUPPLY_PROP_CAPACITY_LEVEL, | |
| POWER_SUPPLY_PROP_TEMP, | |
| POWER_SUPPLY_PROP_TEMP_MAX, | |
| POWER_SUPPLY_PROP_TEMP_MIN, | |
| POWER_SUPPLY_PROP_TEMP_ALERT_MIN, | |
| POWER_SUPPLY_PROP_TEMP_ALERT_MAX, | |
| POWER_SUPPLY_PROP_TEMP_AMBIENT, | |
| POWER_SUPPLY_PROP_TEMP_AMBIENT_ALERT_MIN, | |
| POWER_SUPPLY_PROP_TEMP_AMBIENT_ALERT_MAX, | |
| POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW, | |
| POWER_SUPPLY_PROP_TIME_TO_EMPTY_AVG, | |
| POWER_SUPPLY_PROP_TIME_TO_FULL_NOW, | |
| POWER_SUPPLY_PROP_TIME_TO_FULL_AVG, | |
| POWER_SUPPLY_PROP_TYPE, /* use power_supply.type instead */ | |
| POWER_SUPPLY_PROP_USB_TYPE, | |
| POWER_SUPPLY_PROP_SCOPE, | |
| POWER_SUPPLY_PROP_PRECHARGE_CURRENT, | |
| POWER_SUPPLY_PROP_CHARGE_TERM_CURRENT, | |
| POWER_SUPPLY_PROP_CALIBRATE, | |
| POWER_SUPPLY_PROP_MANUFACTURE_YEAR, | |
| POWER_SUPPLY_PROP_MANUFACTURE_MONTH, | |
| POWER_SUPPLY_PROP_MANUFACTURE_DAY, | |
| POWER_SUPPLY_PROP_INTERNAL_RESISTANCE, | |
| POWER_SUPPLY_PROP_STATE_OF_HEALTH, | |
| /* Properties of type `const char *' */ | |
| POWER_SUPPLY_PROP_MODEL_NAME, | |
| POWER_SUPPLY_PROP_MANUFACTURER, | |
| POWER_SUPPLY_PROP_SERIAL_NUMBER, | |
| }; | |
| enum power_supply_type { | |
| POWER_SUPPLY_TYPE_UNKNOWN = 0, | |
| POWER_SUPPLY_TYPE_BATTERY, | |
| POWER_SUPPLY_TYPE_UPS, | |
| POWER_SUPPLY_TYPE_MAINS, | |
| POWER_SUPPLY_TYPE_USB, /* Standard Downstream Port */ | |
| POWER_SUPPLY_TYPE_USB_DCP, /* Dedicated Charging Port */ | |
| POWER_SUPPLY_TYPE_USB_CDP, /* Charging Downstream Port */ | |
| POWER_SUPPLY_TYPE_USB_ACA, /* Accessory Charger Adapters */ | |
| POWER_SUPPLY_TYPE_USB_TYPE_C, /* Type C Port */ | |
| POWER_SUPPLY_TYPE_USB_PD, /* Power Delivery Port */ | |
| POWER_SUPPLY_TYPE_USB_PD_DRP, /* PD Dual Role Port */ | |
| POWER_SUPPLY_TYPE_APPLE_BRICK_ID, /* Apple Charging Method */ | |
| POWER_SUPPLY_TYPE_WIRELESS, /* Wireless */ | |
| }; | |
| enum power_supply_usb_type { | |
| POWER_SUPPLY_USB_TYPE_UNKNOWN = 0, | |
| POWER_SUPPLY_USB_TYPE_SDP, /* Standard Downstream Port */ | |
| POWER_SUPPLY_USB_TYPE_DCP, /* Dedicated Charging Port */ | |
| POWER_SUPPLY_USB_TYPE_CDP, /* Charging Downstream Port */ | |
| POWER_SUPPLY_USB_TYPE_ACA, /* Accessory Charger Adapters */ | |
| POWER_SUPPLY_USB_TYPE_C, /* Type C Port */ | |
| POWER_SUPPLY_USB_TYPE_PD, /* Power Delivery Port */ | |
| POWER_SUPPLY_USB_TYPE_PD_DRP, /* PD Dual Role Port */ | |
| POWER_SUPPLY_USB_TYPE_PD_PPS, /* PD Programmable Power Supply */ | |
| POWER_SUPPLY_USB_TYPE_APPLE_BRICK_ID, /* Apple Charging Method */ | |
| }; | |
| enum power_supply_charge_behaviour { | |
| POWER_SUPPLY_CHARGE_BEHAVIOUR_AUTO = 0, | |
| POWER_SUPPLY_CHARGE_BEHAVIOUR_INHIBIT_CHARGE, | |
| POWER_SUPPLY_CHARGE_BEHAVIOUR_INHIBIT_CHARGE_AWAKE, | |
| POWER_SUPPLY_CHARGE_BEHAVIOUR_FORCE_DISCHARGE, | |
| }; | |
| enum power_supply_notifier_events { | |
| PSY_EVENT_PROP_CHANGED, | |
| }; | |
| union power_supply_propval { | |
| int intval; | |
| const char *strval; | |
| }; | |
| struct device_node; | |
| struct power_supply; | |
| /* Run-time specific power supply configuration */ | |
| struct power_supply_config { | |
| struct fwnode_handle *fwnode; | |
| /* Driver private data */ | |
| void *drv_data; | |
| /* Device specific sysfs attributes */ | |
| const struct attribute_group **attr_grp; | |
| char **supplied_to; | |
| size_t num_supplicants; | |
| bool no_wakeup_source; | |
| }; | |
| /* Description of power supply */ | |
| struct power_supply_desc { | |
| const char *name; | |
| enum power_supply_type type; | |
| u8 charge_behaviours; | |
| u32 charge_types; | |
| u32 usb_types; | |
| const enum power_supply_property *properties; | |
| size_t num_properties; | |
| /* | |
| * Functions for drivers implementing power supply class. | |
| * These shouldn't be called directly by other drivers for accessing | |
| * this power supply. Instead use power_supply_*() functions (for | |
| * example power_supply_get_property()). | |
| */ | |
| int (*get_property)(struct power_supply *psy, | |
| enum power_supply_property psp, | |
| union power_supply_propval *val); | |
| int (*set_property)(struct power_supply *psy, | |
| enum power_supply_property psp, | |
| const union power_supply_propval *val); | |
| /* | |
| * property_is_writeable() will be called during registration | |
| * of power supply. If this happens during device probe then it must | |
| * not access internal data of device (because probe did not end). | |
| */ | |
| int (*property_is_writeable)(struct power_supply *psy, | |
| enum power_supply_property psp); | |
| void (*external_power_changed)(struct power_supply *psy); | |
| /* | |
| * Set if thermal zone should not be created for this power supply. | |
| * For example for virtual supplies forwarding calls to actual | |
| * sensors or other supplies. | |
| */ | |
| bool no_thermal; | |
| /* For APM emulation, think legacy userspace. */ | |
| int use_for_apm; | |
| }; | |
| struct power_supply_ext { | |
| const char *const name; | |
| u8 charge_behaviours; | |
| u32 charge_types; | |
| const enum power_supply_property *properties; | |
| size_t num_properties; | |
| int (*get_property)(struct power_supply *psy, | |
| const struct power_supply_ext *ext, | |
| void *data, | |
| enum power_supply_property psp, | |
| union power_supply_propval *val); | |
| int (*set_property)(struct power_supply *psy, | |
| const struct power_supply_ext *ext, | |
| void *data, | |
| enum power_supply_property psp, | |
| const union power_supply_propval *val); | |
| int (*property_is_writeable)(struct power_supply *psy, | |
| const struct power_supply_ext *ext, | |
| void *data, | |
| enum power_supply_property psp); | |
| }; | |
| struct power_supply { | |
| const struct power_supply_desc *desc; | |
| char **supplied_to; | |
| size_t num_supplicants; | |
| char **supplied_from; | |
| size_t num_supplies; | |
| /* Driver private data */ | |
| void *drv_data; | |
| /* private */ | |
| struct device dev; | |
| struct work_struct changed_work; | |
| struct delayed_work deferred_register_work; | |
| spinlock_t changed_lock; | |
| bool changed; | |
| bool update_groups; | |
| bool initialized; | |
| bool removing; | |
| atomic_t use_cnt; | |
| struct power_supply_battery_info *battery_info; | |
| struct rw_semaphore extensions_sem; /* protects "extensions" */ | |
| struct list_head extensions; | |
| #ifdef CONFIG_THERMAL | |
| struct thermal_zone_device *tzd; | |
| struct thermal_cooling_device *tcd; | |
| #endif | |
| #ifdef CONFIG_LEDS_TRIGGERS | |
| struct led_trigger *trig; | |
| struct led_trigger *charging_trig; | |
| struct led_trigger *full_trig; | |
| struct led_trigger *charging_blink_full_solid_trig; | |
| struct led_trigger *charging_orange_full_green_trig; | |
| #endif | |
| }; | |
| #define dev_to_psy(__dev) container_of_const(__dev, struct power_supply, dev) | |
| /* | |
| * This is recommended structure to specify static power supply parameters. | |
| * Generic one, parametrizable for different power supplies. Power supply | |
| * class itself does not use it, but that's what implementing most platform | |
| * drivers, should try reuse for consistency. | |
| */ | |
| struct power_supply_info { | |
| const char *name; | |
| int technology; | |
| int voltage_max_design; | |
| int voltage_min_design; | |
| int charge_full_design; | |
| int charge_empty_design; | |
| int energy_full_design; | |
| int energy_empty_design; | |
| int use_for_apm; | |
| }; | |
| struct power_supply_battery_ocv_table { | |
| int ocv; /* microVolts */ | |
| int capacity; /* percent */ | |
| }; | |
| struct power_supply_resistance_temp_table { | |
| int temp; /* celsius */ | |
| int resistance; /* internal resistance percent */ | |
| }; | |
| struct power_supply_vbat_ri_table { | |
| int vbat_uv; /* Battery voltage in microvolt */ | |
| int ri_uohm; /* Internal resistance in microohm */ | |
| }; | |
| /** | |
| * struct power_supply_maintenance_charge_table - setting for maintenace charging | |
| * @charge_current_max_ua: maintenance charging current that is used to keep | |
| * the charge of the battery full as current is consumed after full charging. | |
| * The corresponding charge_voltage_max_uv is used as a safeguard: when we | |
| * reach this voltage the maintenance charging current is turned off. It is | |
| * turned back on if we fall below this voltage. | |
| * @charge_voltage_max_uv: maintenance charging voltage that is usually a bit | |
| * lower than the constant_charge_voltage_max_uv. We can apply this settings | |
| * charge_current_max_ua until we get back up to this voltage. | |
| * @safety_timer_minutes: maintenance charging safety timer, with an expiry | |
| * time in minutes. We will only use maintenance charging in this setting | |
| * for a certain amount of time, then we will first move to the next | |
| * maintenance charge current and voltage pair in respective array and wait | |
| * for the next safety timer timeout, or, if we reached the last maintencance | |
| * charging setting, disable charging until we reach | |
| * charge_restart_voltage_uv and restart ordinary CC/CV charging from there. | |
| * These timers should be chosen to align with the typical discharge curve | |
| * for the battery. | |
| * | |
| * Ordinary CC/CV charging will stop charging when the charge current goes | |
| * below charge_term_current_ua, and then restart it (if the device is still | |
| * plugged into the charger) at charge_restart_voltage_uv. This happens in most | |
| * consumer products because the power usage while connected to a charger is | |
| * not zero, and devices are not manufactured to draw power directly from the | |
| * charger: instead they will at all times dissipate the battery a little, like | |
| * the power used in standby mode. This will over time give a charge graph | |
| * such as this: | |
| * | |
| * Energy | |
| * ^ ... ... ... ... ... ... ... | |
| * | . . . . . . . . . . . . . | |
| * | .. . .. . .. . .. . .. . .. . .. | |
| * |. .. .. .. .. .. .. | |
| * +-------------------------------------------------------------------> t | |
| * | |
| * Practically this means that the Li-ions are wandering back and forth in the | |
| * battery and this causes degeneration of the battery anode and cathode. | |
| * To prolong the life of the battery, maintenance charging is applied after | |
| * reaching charge_term_current_ua to hold up the charge in the battery while | |
| * consuming power, thus lowering the wear on the battery: | |
| * | |
| * Energy | |
| * ^ ....................................... | |
| * | . ...................... | |
| * | .. | |
| * |. | |
| * +-------------------------------------------------------------------> t | |
| * | |
| * Maintenance charging uses the voltages from this table: a table of settings | |
| * is traversed using a slightly lower current and voltage than what is used for | |
| * CC/CV charging. The maintenance charging will for safety reasons not go on | |
| * indefinately: we lower the current and voltage with successive maintenance | |
| * settings, then disable charging completely after we reach the last one, | |
| * and after that we do not restart charging until we reach | |
| * charge_restart_voltage_uv (see struct power_supply_battery_info) and restart | |
| * ordinary CC/CV charging from there. | |
| * | |
| * As an example, a Samsung EB425161LA Lithium-Ion battery is CC/CV charged | |
| * at 900mA to 4340mV, then maintenance charged at 600mA and 4150mV for up to | |
| * 60 hours, then maintenance charged at 600mA and 4100mV for up to 200 hours. | |
| * After this the charge cycle is restarted waiting for | |
| * charge_restart_voltage_uv. | |
| * | |
| * For most mobile electronics this type of maintenance charging is enough for | |
| * the user to disconnect the device and make use of it before both maintenance | |
| * charging cycles are complete, if the current and voltage has been chosen | |
| * appropriately. These need to be determined from battery discharge curves | |
| * and expected standby current. | |
| * | |
| * If the voltage anyway drops to charge_restart_voltage_uv during maintenance | |
| * charging, ordinary CC/CV charging is restarted. This can happen if the | |
| * device is e.g. actively used during charging, so more current is drawn than | |
| * the expected stand-by current. Also overvoltage protection will be applied | |
| * as usual. | |
| */ | |
| struct power_supply_maintenance_charge_table { | |
| int charge_current_max_ua; | |
| int charge_voltage_max_uv; | |
| int charge_safety_timer_minutes; | |
| }; | |
| #define POWER_SUPPLY_OCV_TEMP_MAX 20 | |
| /** | |
| * struct power_supply_battery_info - information about batteries | |
| * @technology: from the POWER_SUPPLY_TECHNOLOGY_* enum | |
| * @energy_full_design_uwh: energy content when fully charged in microwatt | |
| * hours | |
| * @charge_full_design_uah: charge content when fully charged in microampere | |
| * hours | |
| * @voltage_min_design_uv: minimum voltage across the poles when the battery | |
| * is at minimum voltage level in microvolts. If the voltage drops below this | |
| * level the battery will need precharging when using CC/CV charging. | |
| * @voltage_max_design_uv: voltage across the poles when the battery is fully | |
| * charged in microvolts. This is the "nominal voltage" i.e. the voltage | |
| * printed on the label of the battery. | |
| * @tricklecharge_current_ua: the tricklecharge current used when trickle | |
| * charging the battery in microamperes. This is the charging phase when the | |
| * battery is completely empty and we need to carefully trickle in some | |
| * charge until we reach the precharging voltage. | |
| * @precharge_current_ua: current to use in the precharge phase in microamperes, | |
| * the precharge rate is limited by limiting the current to this value. | |
| * @precharge_voltage_max_uv: the maximum voltage allowed when precharging in | |
| * microvolts. When we pass this voltage we will nominally switch over to the | |
| * CC (constant current) charging phase defined by constant_charge_current_ua | |
| * and constant_charge_voltage_max_uv. | |
| * @charge_term_current_ua: when the current in the CV (constant voltage) | |
| * charging phase drops below this value in microamperes the charging will | |
| * terminate completely and not restart until the voltage over the battery | |
| * poles reach charge_restart_voltage_uv unless we use maintenance charging. | |
| * @charge_restart_voltage_uv: when the battery has been fully charged by | |
| * CC/CV charging and charging has been disabled, and the voltage subsequently | |
| * drops below this value in microvolts, the charging will be restarted | |
| * (typically using CV charging). | |
| * @overvoltage_limit_uv: If the voltage exceeds the nominal voltage | |
| * voltage_max_design_uv and we reach this voltage level, all charging must | |
| * stop and emergency procedures take place, such as shutting down the system | |
| * in some cases. | |
| * @constant_charge_current_max_ua: current in microamperes to use in the CC | |
| * (constant current) charging phase. The charging rate is limited | |
| * by this current. This is the main charging phase and as the current is | |
| * constant into the battery the voltage slowly ascends to | |
| * constant_charge_voltage_max_uv. | |
| * @constant_charge_voltage_max_uv: voltage in microvolts signifying the end of | |
| * the CC (constant current) charging phase and the beginning of the CV | |
| * (constant voltage) charging phase. | |
| * @maintenance_charge: an array of maintenance charging settings to be used | |
| * after the main CC/CV charging phase is complete. | |
| * @maintenance_charge_size: the number of maintenance charging settings in | |
| * maintenance_charge. | |
| * @alert_low_temp_charge_current_ua: The charging current to use if the battery | |
| * enters low alert temperature, i.e. if the internal temperature is between | |
| * temp_alert_min and temp_min. No matter the charging phase, this | |
| * and alert_high_temp_charge_voltage_uv will be applied. | |
| * @alert_low_temp_charge_voltage_uv: Same as alert_low_temp_charge_current_ua, | |
| * but for the charging voltage. | |
| * @alert_high_temp_charge_current_ua: The charging current to use if the | |
| * battery enters high alert temperature, i.e. if the internal temperature is | |
| * between temp_alert_max and temp_max. No matter the charging phase, this | |
| * and alert_high_temp_charge_voltage_uv will be applied, usually lowering | |
| * the charging current as an evasive manouver. | |
| * @alert_high_temp_charge_voltage_uv: Same as | |
| * alert_high_temp_charge_current_ua, but for the charging voltage. | |
| * @factory_internal_resistance_uohm: the internal resistance of the battery | |
| * at fabrication time, expressed in microohms. This resistance will vary | |
| * depending on the lifetime and charge of the battery, so this is just a | |
| * nominal ballpark figure. This internal resistance is given for the state | |
| * when the battery is discharging. | |
| * @factory_internal_resistance_charging_uohm: the internal resistance of the | |
| * battery at fabrication time while charging, expressed in microohms. | |
| * The charging process will affect the internal resistance of the battery | |
| * so this value provides a better resistance under these circumstances. | |
| * This resistance will vary depending on the lifetime and charge of the | |
| * battery, so this is just a nominal ballpark figure. | |
| * @ocv_temp: array indicating the open circuit voltage (OCV) capacity | |
| * temperature indices. This is an array of temperatures in degrees Celsius | |
| * indicating which capacity table to use for a certain temperature, since | |
| * the capacity for reasons of chemistry will be different at different | |
| * temperatures. Determining capacity is a multivariate problem and the | |
| * temperature is the first variable we determine. | |
| * @temp_ambient_alert_min: the battery will go outside of operating conditions | |
| * when the ambient temperature goes below this temperature in degrees | |
| * Celsius. | |
| * @temp_ambient_alert_max: the battery will go outside of operating conditions | |
| * when the ambient temperature goes above this temperature in degrees | |
| * Celsius. | |
| * @temp_alert_min: the battery should issue an alert if the internal | |
| * temperature goes below this temperature in degrees Celsius. | |
| * @temp_alert_max: the battery should issue an alert if the internal | |
| * temperature goes above this temperature in degrees Celsius. | |
| * @temp_min: the battery will go outside of operating conditions when | |
| * the internal temperature goes below this temperature in degrees Celsius. | |
| * Normally this means the system should shut down. | |
| * @temp_max: the battery will go outside of operating conditions when | |
| * the internal temperature goes above this temperature in degrees Celsius. | |
| * Normally this means the system should shut down. | |
| * @ocv_table: for each entry in ocv_temp there is a corresponding entry in | |
| * ocv_table and a size for each entry in ocv_table_size. These arrays | |
| * determine the capacity in percent in relation to the voltage in microvolts | |
| * at the indexed temperature. | |
| * @ocv_table_size: for each entry in ocv_temp this array is giving the size of | |
| * each entry in the array of capacity arrays in ocv_table. | |
| * @resist_table: this is a table that correlates a battery temperature to the | |
| * expected internal resistance at this temperature. The resistance is given | |
| * as a percentage of factory_internal_resistance_uohm. Knowing the | |
| * resistance of the battery is usually necessary for calculating the open | |
| * circuit voltage (OCV) that is then used with the ocv_table to calculate | |
| * the capacity of the battery. The resist_table must be ordered descending | |
| * by temperature: highest temperature with lowest resistance first, lowest | |
| * temperature with highest resistance last. | |
| * @resist_table_size: the number of items in the resist_table. | |
| * @vbat2ri_discharging: this is a table that correlates Battery voltage (VBAT) | |
| * to internal resistance (Ri). The resistance is given in microohm for the | |
| * corresponding voltage in microvolts. The internal resistance is used to | |
| * determine the open circuit voltage so that we can determine the capacity | |
| * of the battery. These voltages to resistance tables apply when the battery | |
| * is discharging. The table must be ordered descending by voltage: highest | |
| * voltage first. | |
| * @vbat2ri_discharging_size: the number of items in the vbat2ri_discharging | |
| * table. | |
| * @vbat2ri_charging: same function as vbat2ri_discharging but for the state | |
| * when the battery is charging. Being under charge changes the battery's | |
| * internal resistance characteristics so a separate table is needed.* | |
| * The table must be ordered descending by voltage: highest voltage first. | |
| * @vbat2ri_charging_size: the number of items in the vbat2ri_charging | |
| * table. | |
| * @bti_resistance_ohm: The Battery Type Indicator (BIT) nominal resistance | |
| * in ohms for this battery, if an identification resistor is mounted | |
| * between a third battery terminal and ground. This scheme is used by a lot | |
| * of mobile device batteries. | |
| * @bti_resistance_tolerance: The tolerance in percent of the BTI resistance, | |
| * for example 10 for +/- 10%, if the bti_resistance is set to 7000 and the | |
| * tolerance is 10% we will detect a proper battery if the BTI resistance | |
| * is between 6300 and 7700 Ohm. | |
| * | |
| * This is the recommended struct to manage static battery parameters, | |
| * populated by power_supply_get_battery_info(). Most platform drivers should | |
| * use these for consistency. | |
| * | |
| * Its field names must correspond to elements in enum power_supply_property. | |
| * The default field value is -EINVAL or NULL for pointers. | |
| * | |
| * CC/CV CHARGING: | |
| * | |
| * The charging parameters here assume a CC/CV charging scheme. This method | |
| * is most common with Lithium Ion batteries (other methods are possible) and | |
| * looks as follows: | |
| * | |
| * ^ Battery voltage | |
| * | --- overvoltage_limit_uv | |
| * | | |
| * | ................................................... | |
| * | .. constant_charge_voltage_max_uv | |
| * | .. | |
| * | . | |
| * | . | |
| * | . | |
| * | . | |
| * | . | |
| * | .. precharge_voltage_max_uv | |
| * | .. | |
| * |. (trickle charging) | |
| * +------------------------------------------------------------------> time | |
| * | |
| * ^ Current into the battery | |
| * | | |
| * | ............. constant_charge_current_max_ua | |
| * | . . | |
| * | . . | |
| * | . . | |
| * | . . | |
| * | . .. | |
| * | . .... | |
| * | . ..... | |
| * | ... precharge_current_ua ....... charge_term_current_ua | |
| * | . . | |
| * | . . | |
| * |.... tricklecharge_current_ua . | |
| * | . | |
| * +-----------------------------------------------------------------> time | |
| * | |
| * These diagrams are synchronized on time and the voltage and current | |
| * follow each other. | |
| * | |
| * With CC/CV charging commence over time like this for an empty battery: | |
| * | |
| * 1. When the battery is completely empty it may need to be charged with | |
| * an especially small current so that electrons just "trickle in", | |
| * this is the tricklecharge_current_ua. | |
| * | |
| * 2. Next a small initial pre-charge current (precharge_current_ua) | |
| * is applied if the voltage is below precharge_voltage_max_uv until we | |
| * reach precharge_voltage_max_uv. CAUTION: in some texts this is referred | |
| * to as "trickle charging" but the use in the Linux kernel is different | |
| * see below! | |
| * | |
| * 3. Then the main charging current is applied, which is called the constant | |
| * current (CC) phase. A current regulator is set up to allow | |
| * constant_charge_current_max_ua of current to flow into the battery. | |
| * The chemical reaction in the battery will make the voltage go up as | |
| * charge goes into the battery. This current is applied until we reach | |
| * the constant_charge_voltage_max_uv voltage. | |
| * | |
| * 4. At this voltage we switch over to the constant voltage (CV) phase. This | |
| * means we allow current to go into the battery, but we keep the voltage | |
| * fixed. This current will continue to charge the battery while keeping | |
| * the voltage the same. A chemical reaction in the battery goes on | |
| * storing energy without affecting the voltage. Over time the current | |
| * will slowly drop and when we reach charge_term_current_ua we will | |
| * end the constant voltage phase. | |
| * | |
| * After this the battery is fully charged, and if we do not support maintenance | |
| * charging, the charging will not restart until power dissipation makes the | |
| * voltage fall so that we reach charge_restart_voltage_uv and at this point | |
| * we restart charging at the appropriate phase, usually this will be inside | |
| * the CV phase. | |
| * | |
| * If we support maintenance charging the voltage is however kept high after | |
| * the CV phase with a very low current. This is meant to let the same charge | |
| * go in for usage while the charger is still connected, mainly for | |
| * dissipation for the power consuming entity while connected to the | |
| * charger. | |
| * | |
| * All charging MUST terminate if the overvoltage_limit_uv is ever reached. | |
| * Overcharging Lithium Ion cells can be DANGEROUS and lead to fire or | |
| * explosions. | |
| * | |
| * DETERMINING BATTERY CAPACITY: | |
| * | |
| * Several members of the struct deal with trying to determine the remaining | |
| * capacity in the battery, usually as a percentage of charge. In practice | |
| * many chargers uses a so-called fuel gauge or coloumb counter that measure | |
| * how much charge goes into the battery and how much goes out (+/- leak | |
| * consumption). This does not help if we do not know how much capacity the | |
| * battery has to begin with, such as when it is first used or was taken out | |
| * and charged in a separate charger. Therefore many capacity algorithms use | |
| * the open circuit voltage with a look-up table to determine the rough | |
| * capacity of the battery. The open circuit voltage can be conceptualized | |
| * with an ideal voltage source (V) in series with an internal resistance (Ri) | |
| * like this: | |
| * | |
| * +-------> IBAT >----------------+ | |
| * | ^ | | |
| * [ ] Ri | | | |
| * | | VBAT | | |
| * o <---------- | | | |
| * +| ^ | [ ] Rload | |
| * .---. | | | | |
| * | V | | OCV | | | |
| * '---' | | | | |
| * | | | | | |
| * GND +-------------------------------+ | |
| * | |
| * If we disconnect the load (here simplified as a fixed resistance Rload) | |
| * and measure VBAT with a infinite impedance voltage meter we will get | |
| * VBAT = OCV and this assumption is sometimes made even under load, assuming | |
| * Rload is insignificant. However this will be of dubious quality because the | |
| * load is rarely that small and Ri is strongly nonlinear depending on | |
| * temperature and how much capacity is left in the battery due to the | |
| * chemistry involved. | |
| * | |
| * In many practical applications we cannot just disconnect the battery from | |
| * the load, so instead we often try to measure the instantaneous IBAT (the | |
| * current out from the battery), estimate the Ri and thus calculate the | |
| * voltage drop over Ri and compensate like this: | |
| * | |
| * OCV = VBAT - (IBAT * Ri) | |
| * | |
| * The tables vbat2ri_discharging and vbat2ri_charging are used to determine | |
| * (by interpolation) the Ri from the VBAT under load. These curves are highly | |
| * nonlinear and may need many datapoints but can be found in datasheets for | |
| * some batteries. This gives the compensated open circuit voltage (OCV) for | |
| * the battery even under load. Using this method will also compensate for | |
| * temperature changes in the environment: this will also make the internal | |
| * resistance change, and it will affect the VBAT under load, so correlating | |
| * VBAT to Ri takes both remaining capacity and temperature into consideration. | |
| * | |
| * Alternatively a manufacturer can specify how the capacity of the battery | |
| * is dependent on the battery temperature which is the main factor affecting | |
| * Ri. As we know all checmical reactions are faster when it is warm and slower | |
| * when it is cold. You can put in 1500mAh and only get 800mAh out before the | |
| * voltage drops too low for example. This effect is also highly nonlinear and | |
| * the purpose of the table resist_table: this will take a temperature and | |
| * tell us how big percentage of Ri the specified temperature correlates to. | |
| * Usually we have 100% of the factory_internal_resistance_uohm at 25 degrees | |
| * Celsius. | |
| * | |
| * The power supply class itself doesn't use this struct as of now. | |
| */ | |
| struct power_supply_battery_info { | |
| unsigned int technology; | |
| int energy_full_design_uwh; | |
| int charge_full_design_uah; | |
| int voltage_min_design_uv; | |
| int voltage_max_design_uv; | |
| int tricklecharge_current_ua; | |
| int precharge_current_ua; | |
| int precharge_voltage_max_uv; | |
| int charge_term_current_ua; | |
| int charge_restart_voltage_uv; | |
| int overvoltage_limit_uv; | |
| int constant_charge_current_max_ua; | |
| int constant_charge_voltage_max_uv; | |
| const struct power_supply_maintenance_charge_table *maintenance_charge; | |
| int maintenance_charge_size; | |
| int alert_low_temp_charge_current_ua; | |
| int alert_low_temp_charge_voltage_uv; | |
| int alert_high_temp_charge_current_ua; | |
| int alert_high_temp_charge_voltage_uv; | |
| int factory_internal_resistance_uohm; | |
| int factory_internal_resistance_charging_uohm; | |
| int ocv_temp[POWER_SUPPLY_OCV_TEMP_MAX]; | |
| int temp_ambient_alert_min; | |
| int temp_ambient_alert_max; | |
| int temp_alert_min; | |
| int temp_alert_max; | |
| int temp_min; | |
| int temp_max; | |
| const struct power_supply_battery_ocv_table *ocv_table[POWER_SUPPLY_OCV_TEMP_MAX]; | |
| int ocv_table_size[POWER_SUPPLY_OCV_TEMP_MAX]; | |
| const struct power_supply_resistance_temp_table *resist_table; | |
| int resist_table_size; | |
| const struct power_supply_vbat_ri_table *vbat2ri_discharging; | |
| int vbat2ri_discharging_size; | |
| const struct power_supply_vbat_ri_table *vbat2ri_charging; | |
| int vbat2ri_charging_size; | |
| int bti_resistance_ohm; | |
| int bti_resistance_tolerance; | |
| }; | |
| extern int power_supply_reg_notifier(struct notifier_block *nb); | |
| extern void power_supply_unreg_notifier(struct notifier_block *nb); | |
| #if IS_ENABLED(CONFIG_POWER_SUPPLY) | |
| extern struct power_supply *power_supply_get_by_name(const char *name); | |
| extern void power_supply_put(struct power_supply *psy); | |
| #else | |
| static inline void power_supply_put(struct power_supply *psy) {} | |
| static inline struct power_supply *power_supply_get_by_name(const char *name) | |
| { return NULL; } | |
| #endif | |
| extern struct power_supply *power_supply_get_by_reference(struct fwnode_handle *fwnode, | |
| const char *property); | |
| extern struct power_supply *devm_power_supply_get_by_reference( | |
| struct device *dev, const char *property); | |
| extern const enum power_supply_property power_supply_battery_info_properties[]; | |
| extern const size_t power_supply_battery_info_properties_size; | |
| extern int power_supply_get_battery_info(struct power_supply *psy, | |
| struct power_supply_battery_info **info_out); | |
| extern void power_supply_put_battery_info(struct power_supply *psy, | |
| struct power_supply_battery_info *info); | |
| extern bool power_supply_battery_info_has_prop(struct power_supply_battery_info *info, | |
| enum power_supply_property psp); | |
| extern int power_supply_battery_info_get_prop(struct power_supply_battery_info *info, | |
| enum power_supply_property psp, | |
| union power_supply_propval *val); | |
| extern int power_supply_ocv2cap_simple(const struct power_supply_battery_ocv_table *table, | |
| int table_len, int ocv); | |
| extern const struct power_supply_battery_ocv_table * | |
| power_supply_find_ocv2cap_table(struct power_supply_battery_info *info, | |
| int temp, int *table_len); | |
| extern int power_supply_batinfo_ocv2cap(struct power_supply_battery_info *info, | |
| int ocv, int temp); | |
| extern int | |
| power_supply_temp2resist_simple(const struct power_supply_resistance_temp_table *table, | |
| int table_len, int temp); | |
| extern int power_supply_vbat2ri(struct power_supply_battery_info *info, | |
| int vbat_uv, bool charging); | |
| extern const struct power_supply_maintenance_charge_table * | |
| power_supply_get_maintenance_charging_setting(struct power_supply_battery_info *info, int index); | |
| extern bool power_supply_battery_bti_in_range(struct power_supply_battery_info *info, | |
| int resistance); | |
| extern void power_supply_changed(struct power_supply *psy); | |
| extern int power_supply_am_i_supplied(struct power_supply *psy); | |
| int power_supply_get_property_from_supplier(struct power_supply *psy, | |
| enum power_supply_property psp, | |
| union power_supply_propval *val); | |
| static inline bool | |
| power_supply_supports_maintenance_charging(struct power_supply_battery_info *info) | |
| { | |
| const struct power_supply_maintenance_charge_table *mt; | |
| mt = power_supply_get_maintenance_charging_setting(info, 0); | |
| return (mt != NULL); | |
| } | |
| static inline bool | |
| power_supply_supports_vbat2ri(struct power_supply_battery_info *info) | |
| { | |
| return ((info->vbat2ri_discharging != NULL) && | |
| info->vbat2ri_discharging_size > 0); | |
| } | |
| static inline bool | |
| power_supply_supports_temp2ri(struct power_supply_battery_info *info) | |
| { | |
| return ((info->resist_table != NULL) && | |
| info->resist_table_size > 0); | |
| } | |
| #ifdef CONFIG_POWER_SUPPLY | |
| extern int power_supply_is_system_supplied(void); | |
| #else | |
| static inline int power_supply_is_system_supplied(void) { return -ENOSYS; } | |
| #endif | |
| extern int power_supply_get_property(struct power_supply *psy, | |
| enum power_supply_property psp, | |
| union power_supply_propval *val); | |
| int power_supply_get_property_direct(struct power_supply *psy, enum power_supply_property psp, | |
| union power_supply_propval *val); | |
| #if IS_ENABLED(CONFIG_POWER_SUPPLY) | |
| extern int power_supply_set_property(struct power_supply *psy, | |
| enum power_supply_property psp, | |
| const union power_supply_propval *val); | |
| int power_supply_set_property_direct(struct power_supply *psy, enum power_supply_property psp, | |
| const union power_supply_propval *val); | |
| #else | |
| static inline int power_supply_set_property(struct power_supply *psy, | |
| enum power_supply_property psp, | |
| const union power_supply_propval *val) | |
| { return 0; } | |
| static inline int power_supply_set_property_direct(struct power_supply *psy, | |
| enum power_supply_property psp, | |
| const union power_supply_propval *val) | |
| { return 0; } | |
| #endif | |
| extern void power_supply_external_power_changed(struct power_supply *psy); | |
| extern struct power_supply *__must_check | |
| power_supply_register(struct device *parent, | |
| const struct power_supply_desc *desc, | |
| const struct power_supply_config *cfg); | |
| extern struct power_supply *__must_check | |
| devm_power_supply_register(struct device *parent, | |
| const struct power_supply_desc *desc, | |
| const struct power_supply_config *cfg); | |
| extern void power_supply_unregister(struct power_supply *psy); | |
| extern int power_supply_powers(struct power_supply *psy, struct device *dev); | |
| extern int __must_check | |
| power_supply_register_extension(struct power_supply *psy, | |
| const struct power_supply_ext *ext, | |
| struct device *dev, | |
| void *data); | |
| extern void power_supply_unregister_extension(struct power_supply *psy, | |
| const struct power_supply_ext *ext); | |
| #define to_power_supply(device) container_of(device, struct power_supply, dev) | |
| extern void *power_supply_get_drvdata(struct power_supply *psy); | |
| extern int power_supply_for_each_psy(void *data, int (*fn)(struct power_supply *psy, void *data)); | |
| static inline bool power_supply_is_amp_property(enum power_supply_property psp) | |
| { | |
| switch (psp) { | |
| case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN: | |
| case POWER_SUPPLY_PROP_CHARGE_EMPTY_DESIGN: | |
| case POWER_SUPPLY_PROP_CHARGE_FULL: | |
| case POWER_SUPPLY_PROP_CHARGE_EMPTY: | |
| case POWER_SUPPLY_PROP_CHARGE_NOW: | |
| case POWER_SUPPLY_PROP_CHARGE_AVG: | |
| case POWER_SUPPLY_PROP_CHARGE_COUNTER: | |
| case POWER_SUPPLY_PROP_PRECHARGE_CURRENT: | |
| case POWER_SUPPLY_PROP_CHARGE_TERM_CURRENT: | |
| case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT: | |
| case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX: | |
| case POWER_SUPPLY_PROP_CURRENT_MAX: | |
| case POWER_SUPPLY_PROP_CURRENT_NOW: | |
| case POWER_SUPPLY_PROP_CURRENT_AVG: | |
| case POWER_SUPPLY_PROP_CURRENT_BOOT: | |
| return true; | |
| default: | |
| break; | |
| } | |
| return false; | |
| } | |
| static inline bool power_supply_is_watt_property(enum power_supply_property psp) | |
| { | |
| switch (psp) { | |
| case POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN: | |
| case POWER_SUPPLY_PROP_ENERGY_EMPTY_DESIGN: | |
| case POWER_SUPPLY_PROP_ENERGY_FULL: | |
| case POWER_SUPPLY_PROP_ENERGY_EMPTY: | |
| case POWER_SUPPLY_PROP_ENERGY_NOW: | |
| case POWER_SUPPLY_PROP_ENERGY_AVG: | |
| case POWER_SUPPLY_PROP_VOLTAGE_MAX: | |
| case POWER_SUPPLY_PROP_VOLTAGE_MIN: | |
| case POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN: | |
| case POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN: | |
| case POWER_SUPPLY_PROP_VOLTAGE_NOW: | |
| case POWER_SUPPLY_PROP_VOLTAGE_AVG: | |
| case POWER_SUPPLY_PROP_VOLTAGE_OCV: | |
| case POWER_SUPPLY_PROP_VOLTAGE_BOOT: | |
| case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE: | |
| case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX: | |
| case POWER_SUPPLY_PROP_POWER_NOW: | |
| return true; | |
| default: | |
| break; | |
| } | |
| return false; | |
| } | |
| #ifdef CONFIG_SYSFS | |
| ssize_t power_supply_charge_behaviour_show(struct device *dev, | |
| unsigned int available_behaviours, | |
| enum power_supply_charge_behaviour behaviour, | |
| char *buf); | |
| int power_supply_charge_behaviour_parse(unsigned int available_behaviours, const char *buf); | |
| ssize_t power_supply_charge_types_show(struct device *dev, | |
| unsigned int available_types, | |
| enum power_supply_charge_type current_type, | |
| char *buf); | |
| int power_supply_charge_types_parse(unsigned int available_types, const char *buf); | |
| #else | |
| static inline | |
| ssize_t power_supply_charge_behaviour_show(struct device *dev, | |
| unsigned int available_behaviours, | |
| enum power_supply_charge_behaviour behaviour, | |
| char *buf) | |
| { | |
| return -EOPNOTSUPP; | |
| } | |
| static inline int power_supply_charge_behaviour_parse(unsigned int available_behaviours, | |
| const char *buf) | |
| { | |
| return -EOPNOTSUPP; | |
| } | |
| static inline | |
| ssize_t power_supply_charge_types_show(struct device *dev, | |
| unsigned int available_types, | |
| enum power_supply_charge_type current_type, | |
| char *buf) | |
| { | |
| return -EOPNOTSUPP; | |
| } | |
| static inline int power_supply_charge_types_parse(unsigned int available_types, const char *buf) | |
| { | |
| return -EOPNOTSUPP; | |
| } | |
| #endif | |
| #endif /* __LINUX_POWER_SUPPLY_H__ */ |