| Kernel driver inspur-ipsps1 | 
 | =========================== | 
 |  | 
 | Supported chips: | 
 |  | 
 |   * Inspur Power System power supply unit | 
 |  | 
 | Author: John Wang <wangzqbj@inspur.com> | 
 |  | 
 | Description | 
 | ----------- | 
 |  | 
 | This driver supports Inspur Power System power supplies. This driver | 
 | is a client to the core PMBus driver. | 
 |  | 
 | Usage Notes | 
 | ----------- | 
 |  | 
 | This driver does not auto-detect devices. You will have to instantiate the | 
 | devices explicitly. Please see Documentation/i2c/instantiating-devices.rst for | 
 | details. | 
 |  | 
 | Sysfs entries | 
 | ------------- | 
 |  | 
 | The following attributes are supported: | 
 |  | 
 | ======================= ====================================================== | 
 | curr1_input		Measured input current | 
 | curr1_label		"iin" | 
 | curr1_max		Maximum current | 
 | curr1_max_alarm		Current high alarm | 
 | curr2_input		Measured output current in mA. | 
 | curr2_label		"iout1" | 
 | curr2_crit		Critical maximum current | 
 | curr2_crit_alarm	Current critical high alarm | 
 | curr2_max		Maximum current | 
 | curr2_max_alarm		Current high alarm | 
 |  | 
 | fan1_alarm		Fan 1 warning. | 
 | fan1_fault		Fan 1 fault. | 
 | fan1_input		Fan 1 speed in RPM. | 
 |  | 
 | in1_alarm		Input voltage under-voltage alarm. | 
 | in1_input		Measured input voltage in mV. | 
 | in1_label		"vin" | 
 | in2_input		Measured output voltage in mV. | 
 | in2_label		"vout1" | 
 | in2_lcrit		Critical minimum output voltage | 
 | in2_lcrit_alarm		Output voltage critical low alarm | 
 | in2_max			Maximum output voltage | 
 | in2_max_alarm		Output voltage high alarm | 
 | in2_min			Minimum output voltage | 
 | in2_min_alarm		Output voltage low alarm | 
 |  | 
 | power1_alarm		Input fault or alarm. | 
 | power1_input		Measured input power in uW. | 
 | power1_label		"pin" | 
 | power1_max		Input power limit | 
 | power2_max_alarm	Output power high alarm | 
 | power2_max		Output power limit | 
 | power2_input		Measured output power in uW. | 
 | power2_label		"pout" | 
 |  | 
 | temp[1-3]_input		Measured temperature | 
 | temp[1-2]_max		Maximum temperature | 
 | temp[1-3]_max_alarm	Temperature high alarm | 
 |  | 
 | vendor			Manufacturer name | 
 | model			Product model | 
 | part_number		Product part number | 
 | serial_number		Product serial number | 
 | fw_version		Firmware version | 
 | hw_version		Hardware version | 
 | mode			Work mode. Can be set to active or | 
 | 			standby, when set to standby, PSU will | 
 | 			automatically switch between standby | 
 | 			and redundancy mode. | 
 | ======================= ====================================================== |