| What:		/sys/bus/iio/devices/iio:deviceX/in_voltageY_sensing_mode | 
 | Date:		August 2015 | 
 | KernelVersion:	4.2.0 | 
 | Contact:	source@cogentembedded.com | 
 | Description: | 
 | 		Program sensor type for threshold detector inputs. | 
 | 		Could be either "GND-Open" or "Supply-Open" mode. Y is a | 
 | 		threshold detector input channel. Channels 0..7, 8..15, 16..23 | 
 | 		and 24..31 has common sensor types. | 
 |  | 
 | What:		/sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_falling_value | 
 | Date:		August 2015 | 
 | KernelVersion:	4.2.0 | 
 | Contact:	source@cogentembedded.com | 
 | Description: | 
 | 		Channel Y low voltage threshold. If sensor input voltage goes lower then | 
 | 		this value then the threshold falling event is pushed. | 
 | 		Depending on in_voltageY_sensing_mode the low voltage threshold | 
 | 		is separately set for "GND-Open" and "Supply-Open" modes. | 
 | 		Channels 0..31 have common low threshold values, but could have different | 
 | 		sensing_modes. | 
 |  | 
 | 		The low voltage threshold range is between 2..21V. | 
 | 		Hysteresis between low and high thresholds can not be lower then 2 and | 
 | 		can not be odd. | 
 |  | 
 | 		If falling threshold results hysteresis to odd value then rising | 
 | 		threshold is automatically subtracted by one. | 
 |  | 
 | What:		/sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_rising_value | 
 | Date:		August 2015 | 
 | KernelVersion:	4.2.0 | 
 | Contact:	source@cogentembedded.com | 
 | Description: | 
 | 		Channel Y high voltage threshold. If sensor input voltage goes higher then | 
 | 		this value then the threshold rising event is pushed. | 
 | 		Depending on in_voltageY_sensing_mode the high voltage threshold | 
 | 		is separately set for "GND-Open" and "Supply-Open" modes. | 
 |  | 
 | 		Channels 0..31 have common high threshold values, but could have different | 
 | 		sensing_modes. | 
 |  | 
 | 		The high voltage threshold range is between 3..22V. | 
 | 		Hysteresis between low and high thresholds can not be lower then 2 and | 
 | 		can not be odd. | 
 |  | 
 | 		If rising threshold results hysteresis to odd value then falling | 
 | 		threshold is automatically appended by one. |