| // SPDX-License-Identifier: GPL-2.0-or-later | |
| /* | |
| * Pentium 4/Xeon CPU on demand clock modulation/speed scaling | |
| * (C) 2002 - 2003 Dominik Brodowski <linux@brodo.de> | |
| * (C) 2002 Zwane Mwaikambo <zwane@commfireservices.com> | |
| * (C) 2002 Arjan van de Ven <arjanv@redhat.com> | |
| * (C) 2002 Tora T. Engstad | |
| * All Rights Reserved | |
| * | |
| * The author(s) of this software shall not be held liable for damages | |
| * of any nature resulting due to the use of this software. This | |
| * software is provided AS-IS with no warranties. | |
| * | |
| * Date Errata Description | |
| * 20020525 N44, O17 12.5% or 25% DC causes lockup | |
| */ | |
| #define pr_fmt(fmt) KBUILD_MODNAME ": " fmt | |
| #include <linux/kernel.h> | |
| #include <linux/module.h> | |
| #include <linux/init.h> | |
| #include <linux/smp.h> | |
| #include <linux/cpufreq.h> | |
| #include <linux/cpumask.h> | |
| #include <linux/timex.h> | |
| #include <asm/processor.h> | |
| #include <asm/msr.h> | |
| #include <asm/timer.h> | |
| #include <asm/cpu_device_id.h> | |
| #include "speedstep-lib.h" | |
| /* | |
| * Duty Cycle (3bits), note DC_DISABLE is not specified in | |
| * intel docs i just use it to mean disable | |
| */ | |
| enum { | |
| DC_RESV, DC_DFLT, DC_25PT, DC_38PT, DC_50PT, | |
| DC_64PT, DC_75PT, DC_88PT, DC_DISABLE | |
| }; | |
| #define DC_ENTRIES 8 | |
| static int has_N44_O17_errata[NR_CPUS]; | |
| static unsigned int stock_freq; | |
| static struct cpufreq_driver p4clockmod_driver; | |
| static unsigned int cpufreq_p4_get(unsigned int cpu); | |
| static int cpufreq_p4_setdc(unsigned int cpu, unsigned int newstate) | |
| { | |
| u32 l, h; | |
| if ((newstate > DC_DISABLE) || (newstate == DC_RESV)) | |
| return -EINVAL; | |
| rdmsr_on_cpu(cpu, MSR_IA32_THERM_STATUS, &l, &h); | |
| if (l & 0x01) | |
| pr_debug("CPU#%d currently thermal throttled\n", cpu); | |
| if (has_N44_O17_errata[cpu] && | |
| (newstate == DC_25PT || newstate == DC_DFLT)) | |
| newstate = DC_38PT; | |
| rdmsr_on_cpu(cpu, MSR_IA32_THERM_CONTROL, &l, &h); | |
| if (newstate == DC_DISABLE) { | |
| pr_debug("CPU#%d disabling modulation\n", cpu); | |
| wrmsr_on_cpu(cpu, MSR_IA32_THERM_CONTROL, l & ~(1<<4), h); | |
| } else { | |
| pr_debug("CPU#%d setting duty cycle to %d%%\n", | |
| cpu, ((125 * newstate) / 10)); | |
| /* bits 63 - 5 : reserved | |
| * bit 4 : enable/disable | |
| * bits 3-1 : duty cycle | |
| * bit 0 : reserved | |
| */ | |
| l = (l & ~14); | |
| l = l | (1<<4) | ((newstate & 0x7)<<1); | |
| wrmsr_on_cpu(cpu, MSR_IA32_THERM_CONTROL, l, h); | |
| } | |
| return 0; | |
| } | |
| static struct cpufreq_frequency_table p4clockmod_table[] = { | |
| {0, DC_RESV, CPUFREQ_ENTRY_INVALID}, | |
| {0, DC_DFLT, 0}, | |
| {0, DC_25PT, 0}, | |
| {0, DC_38PT, 0}, | |
| {0, DC_50PT, 0}, | |
| {0, DC_64PT, 0}, | |
| {0, DC_75PT, 0}, | |
| {0, DC_88PT, 0}, | |
| {0, DC_DISABLE, 0}, | |
| {0, DC_RESV, CPUFREQ_TABLE_END}, | |
| }; | |
| static int cpufreq_p4_target(struct cpufreq_policy *policy, unsigned int index) | |
| { | |
| int i; | |
| /* run on each logical CPU, | |
| * see section 13.15.3 of IA32 Intel Architecture Software | |
| * Developer's Manual, Volume 3 | |
| */ | |
| for_each_cpu(i, policy->cpus) | |
| cpufreq_p4_setdc(i, p4clockmod_table[index].driver_data); | |
| return 0; | |
| } | |
| static unsigned int cpufreq_p4_get_frequency(struct cpuinfo_x86 *c) | |
| { | |
| if (c->x86 == 0x06) { | |
| if (cpu_has(c, X86_FEATURE_EST)) | |
| pr_warn_once("Warning: EST-capable CPU detected. The acpi-cpufreq module offers voltage scaling in addition to frequency scaling. You should use that instead of p4-clockmod, if possible.\n"); | |
| switch (c->x86_model) { | |
| case 0x0E: /* Core */ | |
| case 0x0F: /* Core Duo */ | |
| case 0x16: /* Celeron Core */ | |
| case 0x1C: /* Atom */ | |
| p4clockmod_driver.flags |= CPUFREQ_CONST_LOOPS; | |
| return speedstep_get_frequency(SPEEDSTEP_CPU_PCORE); | |
| case 0x0D: /* Pentium M (Dothan) */ | |
| p4clockmod_driver.flags |= CPUFREQ_CONST_LOOPS; | |
| fallthrough; | |
| case 0x09: /* Pentium M (Banias) */ | |
| return speedstep_get_frequency(SPEEDSTEP_CPU_PM); | |
| } | |
| } | |
| if (c->x86 != 0xF) | |
| return 0; | |
| /* on P-4s, the TSC runs with constant frequency independent whether | |
| * throttling is active or not. */ | |
| p4clockmod_driver.flags |= CPUFREQ_CONST_LOOPS; | |
| if (speedstep_detect_processor() == SPEEDSTEP_CPU_P4M) { | |
| pr_warn("Warning: Pentium 4-M detected. The speedstep-ich or acpi cpufreq modules offer voltage scaling in addition of frequency scaling. You should use either one instead of p4-clockmod, if possible.\n"); | |
| return speedstep_get_frequency(SPEEDSTEP_CPU_P4M); | |
| } | |
| return speedstep_get_frequency(SPEEDSTEP_CPU_P4D); | |
| } | |
| static int cpufreq_p4_cpu_init(struct cpufreq_policy *policy) | |
| { | |
| struct cpuinfo_x86 *c = &cpu_data(policy->cpu); | |
| int cpuid = 0; | |
| unsigned int i; | |
| #ifdef CONFIG_SMP | |
| cpumask_copy(policy->cpus, topology_sibling_cpumask(policy->cpu)); | |
| #endif | |
| /* Errata workaround */ | |
| cpuid = (c->x86 << 8) | (c->x86_model << 4) | c->x86_stepping; | |
| switch (cpuid) { | |
| case 0x0f07: | |
| case 0x0f0a: | |
| case 0x0f11: | |
| case 0x0f12: | |
| has_N44_O17_errata[policy->cpu] = 1; | |
| pr_debug("has errata -- disabling low frequencies\n"); | |
| } | |
| if (speedstep_detect_processor() == SPEEDSTEP_CPU_P4D && | |
| c->x86_model < 2) { | |
| /* switch to maximum frequency and measure result */ | |
| cpufreq_p4_setdc(policy->cpu, DC_DISABLE); | |
| recalibrate_cpu_khz(); | |
| } | |
| /* get max frequency */ | |
| stock_freq = cpufreq_p4_get_frequency(c); | |
| if (!stock_freq) | |
| return -EINVAL; | |
| /* table init */ | |
| for (i = 1; (p4clockmod_table[i].frequency != CPUFREQ_TABLE_END); i++) { | |
| if ((i < 2) && (has_N44_O17_errata[policy->cpu])) | |
| p4clockmod_table[i].frequency = CPUFREQ_ENTRY_INVALID; | |
| else | |
| p4clockmod_table[i].frequency = (stock_freq * i)/8; | |
| } | |
| /* cpuinfo and default policy values */ | |
| /* the transition latency is set to be 1 higher than the maximum | |
| * transition latency of the ondemand governor */ | |
| policy->cpuinfo.transition_latency = 10000001; | |
| policy->freq_table = &p4clockmod_table[0]; | |
| return 0; | |
| } | |
| static unsigned int cpufreq_p4_get(unsigned int cpu) | |
| { | |
| u32 l, h; | |
| rdmsr_on_cpu(cpu, MSR_IA32_THERM_CONTROL, &l, &h); | |
| if (l & 0x10) { | |
| l = l >> 1; | |
| l &= 0x7; | |
| } else | |
| l = DC_DISABLE; | |
| if (l != DC_DISABLE) | |
| return stock_freq * l / 8; | |
| return stock_freq; | |
| } | |
| static struct cpufreq_driver p4clockmod_driver = { | |
| .verify = cpufreq_generic_frequency_table_verify, | |
| .target_index = cpufreq_p4_target, | |
| .init = cpufreq_p4_cpu_init, | |
| .get = cpufreq_p4_get, | |
| .name = "p4-clockmod", | |
| .attr = cpufreq_generic_attr, | |
| }; | |
| static const struct x86_cpu_id cpufreq_p4_id[] = { | |
| X86_MATCH_VENDOR_FEATURE(INTEL, X86_FEATURE_ACC, NULL), | |
| {} | |
| }; | |
| /* | |
| * Intentionally no MODULE_DEVICE_TABLE here: this driver should not | |
| * be auto loaded. Please don't add one. | |
| */ | |
| static int __init cpufreq_p4_init(void) | |
| { | |
| int ret; | |
| /* | |
| * THERM_CONTROL is architectural for IA32 now, so | |
| * we can rely on the capability checks | |
| */ | |
| if (!x86_match_cpu(cpufreq_p4_id) || !boot_cpu_has(X86_FEATURE_ACPI)) | |
| return -ENODEV; | |
| ret = cpufreq_register_driver(&p4clockmod_driver); | |
| if (!ret) | |
| pr_info("P4/Xeon(TM) CPU On-Demand Clock Modulation available\n"); | |
| return ret; | |
| } | |
| static void __exit cpufreq_p4_exit(void) | |
| { | |
| cpufreq_unregister_driver(&p4clockmod_driver); | |
| } | |
| MODULE_AUTHOR("Zwane Mwaikambo <zwane@commfireservices.com>"); | |
| MODULE_DESCRIPTION("cpufreq driver for Pentium(TM) 4/Xeon(TM)"); | |
| MODULE_LICENSE("GPL"); | |
| late_initcall(cpufreq_p4_init); | |