Use changed serial port config name for Bayleybay too

An earlier change modified the serial port configuration option name
and updated most board configurations, but Bayleybay was left behind.

BUG=None
TEST=Baylebay builds smoothly again

Change-Id: I8b779c1fb24820ca5ff95dcd6641ae1df94f7e1b
Signed-off-by: Vadim Bendebury <vbendeb@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/170961
Reviewed-by: Aaron Durbin <adurbin@chromium.org>
diff --git a/payloads/libpayload/configs/config.bayleybay b/payloads/libpayload/configs/config.bayleybay
index cab7bf9..16fddc8 100644
--- a/payloads/libpayload/configs/config.bayleybay
+++ b/payloads/libpayload/configs/config.bayleybay
@@ -34,7 +34,7 @@
 CONFIG_LP_SKIP_CONSOLE_INIT=y
 CONFIG_LP_CBMEM_CONSOLE=y
 CONFIG_LP_SERIAL_CONSOLE=y
-CONFIG_LP_X86_SERIAL_CONSOLE=y
+CONFIG_LP_8250_SERIAL_CONSOLE=y
 CONFIG_LP_SERIAL_IOBASE=0x3f8
 # CONFIG_LP_SERIAL_SET_SPEED is not set
 # CONFIG_LP_SERIAL_ACS_FALLBACK is not set