blob: 7741ea5647ee994a3d8900911cd1663e86fe252e [file] [log] [blame] [edit]
# Copyright 2017 The Chromium OS Authors. All rights reserved.
# Use of this source code is governed by a BSD-style license that can be
# found in the LICENSE file.
import logging
from autotest_lib.client.common_lib import error
from autotest_lib.client.common_lib.cros import cr50_utils
from autotest_lib.server.cros import filesystem_util
from autotest_lib.server.cros.faft.cr50_test import Cr50Test
class firmware_Cr50SetBoardId(Cr50Test):
"""Verify cr50-set-board-id.sh
Verify cr50-set-board-id sets the correct board id and flags based on the
given stage.
"""
version = 1
BID_SCRIPT = '/usr/share/cros/cr50-set-board-id.sh'
# the command to get the brand name
GET_BRAND = 'cros_config / brand-code'
# Used when the flags were not initialized in the factory.
UNKNOWN_FLAGS = 0xff00
# Used for dev, proto, EVT, and DVT phases.
DEVELOPMENT_FLAGS = 0x7f7f
# Used for PVT and MP builds.
RELEASE_FLAGS = 0x7f80
TEST_MP_FLAGS = 0x10000
PHASE_FLAGS_DICT = {
'unknown' : UNKNOWN_FLAGS,
'dev' : DEVELOPMENT_FLAGS,
'proto' : DEVELOPMENT_FLAGS,
'evt' : DEVELOPMENT_FLAGS,
'dvt' : DEVELOPMENT_FLAGS,
'mp' : RELEASE_FLAGS,
'pvt' : RELEASE_FLAGS,
}
# The response strings from cr50-set-board-id
SUCCESS = ["Successfully updated board ID to 'BID' with phase 'PHASE'.",
0]
ERROR_UNKNOWN_PHASE = ['Unknown phase (PHASE)', 1]
ERROR_INVALID_RLZ = ['Invalid RLZ brand code (BID).', 1]
ERROR_ALREADY_SET = ['Board ID and flag have already been set.', 2]
ERROR_BID_SET_DIFFERENTLY = ['Board ID has been set differently.', 3]
ERROR_FLAG_SET_DIFFERENTLY = ['Flag has been set differently.', 3]
ERROR_BID_MISMATCH = ['Error 5 while setting board id', 1]
def initialize(self, host, cmdline_args, full_args, bid=''):
# Restore the original image, rlz code, and board id during cleanup.
super(firmware_Cr50SetBoardId, self).initialize(host, cmdline_args,
full_args, restore_cr50_image=True, restore_cr50_board_id=True)
if self.servo.main_device_is_ccd():
raise error.TestNAError('Use a flex cable instead of CCD cable.')
result = self.host.run(self.GET_BRAND, ignore_status=True)
platform_brand = result.stdout.strip()
if result.exit_status or not platform_brand:
raise error.TestNAError('Could not get "cros_config / brand-code"')
self.platform_brand = platform_brand
bid = self.get_saved_cr50_original_version()[2]
self._bid_flags = int(bid.rsplit(':', 1)[-1], 16) if bid else 0
if self._bid_flags == self.TEST_MP_FLAGS:
raise error.TestNAError('cr50-set-board-id cannot be used with '
'test mp images.')
filesystem_util.make_rootfs_writable(self.host)
self.host.run('rm %s' % cr50_utils.CR50_PREPVT, ignore_status=True)
self.host.run('rm %s' % cr50_utils.CR50_PROD, ignore_status=True)
def run_script(self, expected_result, phase, board_id=''):
"""Run the bid script with the given phase and board id
Args:
expected_result: a list with the result message and exit status
phase: The phase string.
board_id: The board id string.
Raises:
TestFail if the expected result message did not match the script
output
"""
message, exit_status = expected_result
# If we expect an error ignore the exit status
ignore_status = not not exit_status
# Run the script with the phase and board id
cmd = '%s %s %s' % (self.BID_SCRIPT, phase, board_id)
result = self.host.run(cmd, ignore_status=ignore_status)
# If we don't give the script a board id, it will use the platform
# brand
expected_board_id = board_id if board_id else self.platform_brand
# Replace the placeholders with the expected board id and phase
message = message.replace('BID', expected_board_id)
message = message.replace('PHASE', phase)
logging.info(result.stdout)
# Compare the expected script output to the actual script result
if message not in result.stdout or exit_status != result.exit_status:
logging.debug(result)
raise error.TestFail('Expected "%s" got "%s"' % (message,
result.stdout))
def eraseflashinfo(self):
"""Eraseflashinfo if the board id is set."""
if cr50_utils.GetChipBoardId(self.host) == cr50_utils.ERASED_CHIP_BID:
return
# Erase the board id so we can change it.
self.eraseflashinfo_and_restore_image()
def run_once(self):
"""Verify cr50-set-board-id.sh"""
self.eraseflashinfo()
# 'A' is too short to be a valid rlz code
self.run_script(self.ERROR_INVALID_RLZ, 'dvt', 'A')
# dummy_phase is not a valid phase
self.run_script(self.ERROR_UNKNOWN_PHASE, 'dummy_phase')
# The rlz code is checked after the phase
self.run_script(self.ERROR_UNKNOWN_PHASE, 'dummy_phase', 'A')
self.eraseflashinfo()
# Set the board id so we can verify cr50-set-board-id has the correct
# response to the board id already being set.
self.run_script(self.SUCCESS, 'dvt', 'TEST')
# mp has different flags than dvt
self.run_script(self.ERROR_FLAG_SET_DIFFERENTLY, 'mp', 'TEST')
# try setting the dvt flags with a different board id
self.run_script(self.ERROR_BID_SET_DIFFERENTLY, 'dvt', 'test')
# running with the same phase and board id will raise an error that the
# board id is already set
self.run_script(self.ERROR_ALREADY_SET, 'dvt', 'TEST')
# Verify each stage sets the right flags
for phase, flags in self.PHASE_FLAGS_DICT.iteritems():
self.eraseflashinfo()
expected_response = self.SUCCESS
expected_brand = self.platform_brand
expected_flags = flags
if self._bid_flags & flags != self._bid_flags:
expected_response = self.ERROR_BID_MISMATCH
expected_brand = cr50_utils.ERASED_BID_INT
expected_flags = cr50_utils.ERASED_BID_INT
logging.info('%s phase mismatch with current image', phase)
# Run the script to set the board id and flags for the given phase.
self.run_script(expected_response, phase)
# Check that the board id and flags are actually set.
cr50_utils.CheckChipBoardId(self.host, expected_brand,
expected_flags)